ABB, 12kV CCV SafeLink CB RMU
12kV SafeLink CB RMU 12kV SafeLink CB RMU ,ABB MAKE
HT Panel Outdoor type (RMU UNIT) :- 1 No. 11KV, 400/630A 21KA/3 Sec outdoor type, Non-extensible Manual Operated SF6 gas insulated Ring Main Unit with 2Nos. load Switches 1No. Vacuum Circuit breaker enclosed in a stainless steel tank with self powered microprocessor bases numerical relay and dedicated CT’s for protection of Transformer.-
LOAD BREAK SWITCH 1 :
SafeLink CB C is a cable switch module with a three position load break switch and earthing switch, busbars, interlocking and earthbar with Side Cable Termination
1 SafeLink CB type C: Cable switch 12kV, 630A 1 Manometer 1 Snap action mech. for manual operation 1 Cable cover standard with Interlocking 1 Cable bushings interface C (400 bolted), 630 A, standard 1 Capacitive voltage indication fixed type VPIS 9-15 kV 1 Cable support bars, standard for 1-way unit
LOAD BREAK SWITCH 2 :
SafeLink CB C is a cable switch module with a three position load break switch and earthing switch, busbars, interlocking and earthbar. with Side Cable Termination
1 SafeLink CB type C: Cable switch 12kV, 630A 1 Snap action mech. for manual operation 1 Cable cover standard with Interlocking 1 Cable bushings interface C (400 bolted), 630 A, standard 1 Capacitive voltage indication fixed type VPIS 9-15 kV 1 Cable support bars, standard for 1-way unit
VCB 1 :
SafeLink CB V is a Vacuum circuit breaker module with vacuum circuit breaker, three position isolator/earthing switch, busbars, interlocking, earthbar and stored spring energy with Rear Cable Termination
1 SafeLink CB type V: Vacuum circuit breaker 12kV, 630A 1 Self Powered Over Current and Earth Fault protection relay ADR141S 1 Cable bushings interface C (400 bolted), 630A 1 Capacitive voltage indication fixed type VPIS 6-12 kV 3 Ring core current transformer type 100/1 A, 2.5VA, 5P10 for protection 1 Aux. contacts for VCB & Earth Position 1 Stored energy mech. EL2 for Manual operation
Data sheet
- RMU RELAY
- SELF POWERED RELAY
- COUNTRY OF ORIGIN
- INDIA
- RMU MANOMETER
- REQUIRED
- RMU ANNUNCIATOR
- NOT REQUIRED
- RMU MULTIFUNCTION METER REQUIREMENT
- NOT REQUIRED IN VCB
- RMU AMMETER REQUIREMENT
- NOT REQUIRED
- RMU SCADA COMPATIBILITY
- NO
- RMU SHORT CIRCUIT FPI WITH CONTACT
- NOT REQUIRED
- RMU SHORT CIRCUIT FPI
- NOT REQUIRED
- RMU EARTH FAULT FPI
- NOT REQUIRED
- RMU VOLTAGE RATING
- 11KV
- RMU METERING PT
- NO PT REQUIRED
- RMU BATTERY & CHARGER
- NOT REQUIRED
- RMU OPERATION
- MANUAL WITHOUT SCADA CONTACT
- RMU CONFIGURATION
- ONE VCB
- RMU CONFIGURATION
- TWO ISOLATORS
- RMU EXTENSIBILITY
- NON EXTENSIBLE
- RMU APPLICATION
- OUTDOOR IP54
- RMU STC RATING
- 21KA FOR 3 SECONDS
- RMU CURRENT RATING
- 630A