12kV SafeLink CB ABB RMU
    • 12kV SafeLink CB ABB RMU

    ABB, 12kV CCV SafeLink CB RMU

    12kV SafeLink CB RMU 12kV SafeLink CB RMU ,ABB MAKE

    • Standalone (integration)
    • Facebook messenger (link)
    • WhatsApp (link)
    • Viber (link)
    • Skype (link)
    • Send an email (link)
    • Telegram (link)
    • Tawk.to (integration)
    • Facebook messenger (integration)
    • Crisp (integration)
    • Tidio (integration)

    HT Panel Outdoor type (RMU UNIT) :- 1 No. 11KV, 400/630A 21KA/3 Sec outdoor type, Non-extensible Manual Operated SF6 gas insulated Ring Main Unit  with 2Nos. load Switches 1No. Vacuum Circuit breaker enclosed in a stainless steel tank with self powered microprocessor bases numerical relay and dedicated CT’s for protection of Transformer.-

    LOAD BREAK SWITCH 1 :

    SafeLink CB C is a cable switch module with a three position load break switch and earthing switch, busbars, interlocking and earthbar with Side Cable Termination

    1 SafeLink CB type C: Cable switch 12kV, 630A 1 Manometer 1 Snap action mech. for manual operation 1 Cable cover standard with Interlocking 1 Cable bushings interface C (400 bolted), 630 A, standard 1 Capacitive voltage indication fixed type VPIS 9-15 kV 1 Cable support bars, standard for 1-way unit

    LOAD BREAK SWITCH 2 :

    SafeLink CB C is a cable switch module with a three position load break switch and earthing switch, busbars, interlocking and earthbar. with Side Cable Termination

    1 SafeLink CB type C: Cable switch 12kV, 630A 1 Snap action mech. for manual operation 1 Cable cover standard with Interlocking 1 Cable bushings interface C (400 bolted), 630 A, standard 1 Capacitive voltage indication fixed type VPIS 9-15 kV 1 Cable support bars, standard for 1-way unit

    VCB 1 :

    SafeLink CB V is a Vacuum circuit breaker module with vacuum circuit breaker, three position isolator/earthing switch, busbars, interlocking, earthbar and stored spring energy with Rear Cable Termination

    1 SafeLink CB type V: Vacuum circuit breaker 12kV, 630A 1 Self Powered Over Current and Earth Fault protection relay ADR141S 1 Cable bushings interface C (400 bolted), 630A 1 Capacitive voltage indication fixed type VPIS 6-12 kV 3 Ring core current transformer type 100/1 A, 2.5VA, 5P10 for protection 1 Aux. contacts for VCB & Earth Position 1 Stored energy mech. EL2 for Manual operation

    Data sheet

    RMU RELAY
    SELF POWERED RELAY
    COUNTRY OF ORIGIN
    INDIA
    RMU MANOMETER
    REQUIRED
    RMU ANNUNCIATOR
    NOT REQUIRED
    RMU MULTIFUNCTION METER REQUIREMENT
    NOT REQUIRED IN VCB
    RMU AMMETER REQUIREMENT
    NOT REQUIRED
    RMU SCADA COMPATIBILITY
    NO
    RMU SHORT CIRCUIT FPI WITH CONTACT
    NOT REQUIRED
    RMU SHORT CIRCUIT FPI
    NOT REQUIRED
    RMU EARTH FAULT FPI
    NOT REQUIRED
    RMU VOLTAGE RATING
    11KV
    RMU METERING PT
    NO PT REQUIRED
    RMU BATTERY & CHARGER
    NOT REQUIRED
    RMU OPERATION
    MANUAL WITHOUT SCADA CONTACT
    RMU CONFIGURATION
    ONE VCB
    RMU CONFIGURATION
    TWO ISOLATORS
    RMU EXTENSIBILITY
    NON EXTENSIBLE
    RMU APPLICATION
    OUTDOOR IP54
    RMU STC RATING
    21KA FOR 3 SECONDS
    RMU CURRENT RATING
    630A

    Specific References

    New

    Download

    SAFELINK CB ABB CATALOGUE

    Download (147.66KB)