L&T, 12-20A, 1.5HP, MF-G1 with Ammeter and Voltmeter SUBMERSIBLE PUMP CONTROLLER
C&S, 80HP, AUTOMATIC STAR...
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D/LR1D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Hour meter( To monitor SPCU power ON hours),RYB LED indicator,Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection
C&S, 12HP, 3 Phase, DOL,...
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, On / Off Rocker switch, Motor ON & Trip LED Indicator.
C&S, 7.5HP, AUTOMATIC STAR...
Incorporating Heavy Duty 4 Pole Contactor type TC1-DX, Overload relay type LR3D/LR1D, Auto Start Switch, 3 Position selector switch for SPP Auto/SPP Manual / Manual, Voltmeter with Selector Switch, Suppressed scale Ammeter, RYB LED Indicator Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection.
C&S, 1.5HP, 1 Phase,...
Incorporating DP Contactor, fixed current relay; Digital VA meter & Start and Run Capacitor with MCB.
C&S, 40HP, 3 Phase,...
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D/LR1D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Rocker Switch (ON/OFF) Hour meter (To monitor SPCU power ON hours), RYB LED indicator, Motor ON & Trip LED Indicator
C&S, 10HP, 3 Phase,...
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Voltmeter with Selector Switch, Suppressed scale Ammeter, Motor ON & Trip LED Indicator, TP 'C' Curve MCB for short circuit protection.
C&S, 12/15HP, 3 Phase,...
Incorporating Heavy Duty 4 Pole Contactor type TC1-DX, Overload relay type LR3D/LR1D, Auto Start Switch, 3 Position selector switch for SPP Auto/SPP Manual / Manual (AS4), Voltmeter with Selector Switch, Suppressed scale Ammeter, Motor ON & Trip LED indicator with rigid Busbar.
C&S, 25HP, 3 Phase, DOL,...
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual (AS4), On / Off Rocker switch, RYB LED indicator, Motor ON & Trip LED Indicator.
C&S, 2HP, 1 Phase,...
Incorporating Single Phase Economical Submersible pump control unit with DP Contactor, fixed current relay; Dual analog VA meter & Start and Run capacitor.
C&S, 20HP, 3 Phase,...
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D/LR1D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Rocker Switch (ON/OFF) Hour meter (To monitor SPCU power ON hours), RYB LED indicator, Motor ON & Trip LED Indicator
C&S, 1HP, 1 Phase, DELUXE...
Incorporating Heavy duty 2 Pole Contactor with Overload Relay Type CS1, Supressed scale Voltmeter & Ammeter with provision of terminals for dry run.
C&S, 1HP, 1 Phase,...
Incorporating DP Contactor, fixed current relay; Digital VA meter & Start and Run Capacitor with MCB.
C&S, 1HP, 1 Phase,...
Incorporating Single Phase Economical Submersible pump control unit with DP Contactor, fixed current relay; Dual analog VA meter & Start and Run capacitor.





