L&T, 13-21A, 10HP, MU-G10 DOL SUBMERSIBLE PUMP CONTROLLER
C&S, 25HP, AUTOMATIC STAR...
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D/LR1D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Hour meter( To monitor SPCU power ON hours),RYB LED indicator,Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection
C&S, 1HP, 1 Phase,...
Incorporating Single Phase Economical Submersible pump control unit with DP Contactor, fixed current relay; Dual analog VA meter & run capacitor.
C&S, 40HP, 3 Phase,...
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D/LR1D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Rocker Switch (ON/OFF) Hour meter (To monitor SPCU power ON hours), RYB LED indicator, Motor ON & Trip LED Indicator
C&S, 1HP, 1 Phase, DELUXE...
Incorporating Heavy duty 2 Pole Contactor with Overload Relay Type CS1, Supressed scale Voltmeter & Ammeter with provision of terminals for dry run.
C&S, 15HP, DOL With Hour...
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Hour meter ( To monitor SPCU power ON hours), Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection.
C&S, 1.5HP, 1 Phase,...
Incorporating DP Contactor, fixed current relay; Digital VA meter & Start and Run Capacitor with MCB.
C&S, 5.5HP, 3 Phase,...
Incorporating Heavy Duty 4 Pole Contactor type TC1-DX, Overload relay type LR3D/LR1D, Auto Start Switch, 3 Position selector switch for SPP Auto/SPP Manual / Manual (AS4), Voltmeter with Selector Switch, Suppressed scale Ammeter, Motor ON & Trip LED indicator with rigid Busbar.
C&S, 5/5.5HP, 3 Phase, DOL,...
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, On / Off Rocker switch, Motor ON & Trip LED Indicator.
C&S, 2HP, 1 Phase, DELUXE...
Incorporating Heavy duty 2 Pole Contactor, 2P Overload Relay Type LR7D, Supressed scale Voltmeter & Ammeter with provision of terminals for dry run relay.
C&S, 5.5HP, 3 Phase,...
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D/LR1D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Rocker Switch (ON/OFF) Hour meter (To monitor SPCU power ON hours), RYB LED indicator, Motor ON & Trip LED Indicator
C&S, 30HP, 3 Phase, DOL,...
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual (AS4), On / Off Rocker switch, RYB LED indicator, Motor ON & Trip LED Indicator.