C&S, 25HP, 3PH, AUTOMATIC...
Incorporating Heavy Duty 4 Pole Contactor type TC1-DX with wide band operating coil, overload type LR1D with pneumatic motor.
Incorporating Single Phase Economical Submersible pump control unit with DP Contactor, fixed current relay; Dual analog VA meter & run capacitor.
Features of Submersible Pump Starter
Incorporating Heavy Duty 4 Pole Contactor type TC1-DX with wide band operating coil, overload type LR1D with pneumatic motor.
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Hour meter ( To monitor SPCU power ON hours), Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection.
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D/LR1D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Rocker Switch (ON/OFF) Hour meter (To monitor SPCU power ON hours), RYB LED indicator, Motor ON & Trip LED Indicator
Incorporating Heavy Duty 4 Pole Contactor type TC1-DX, Overload relay type LR3D/LR1D, Auto Start Switch, 3 Position selector switch for SPP Auto/SPP Manual / Manual (AS4), Voltmeter with Selector Switch, Suppressed scale Ammeter, Motor ON & Trip LED indicator with rigid Busbar.
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D/LR1D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Rocker Switch (ON/OFF) Hour meter (To monitor SPCU power ON hours), RYB LED indicator, Motor ON & Trip LED Indicator
Incorporating 2 Pole Definite Purpose Contactor, 2 Pole Oveload relay type LR7DM, Ammeter, Voltmeter ON/OFF Push Button, Motor ON Indicator with provision of terminal for dry run relay.
Incorporating 2 Pole Definite Purpose Contactor, Single Pole MCB, Ammeter, ON/OFF Push button, Motor ON indicator with provision of terminal for dry run relay
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Voltmeter with Selector Switch, Suppressed scale Ammeter, Motor ON & Trip LED Indicator, TP 'C' Curve MCB for short circuit protection.
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, On / Off Rocker switch, Motor ON & Trip LED Indicator.
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D/LR1D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Hour meter( To monitor SPCU power ON hours),RYB LED indicator,Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection
Incorporating 2 Pole Definite Purpose Contactor, 2 Pole Oveload relay type LR7DM, Ammeter, Voltmeter ON/OFF Push Button, Motor ON Indicator with provision of terminal for dry run relay.
Incorporating Single Phase Economical Submersible pump control unit with DP Contactor, fixed current relay; Dual analog VA meter & Start and Run capacitor.