SCHNEIDER, 4 Pole, 1250A, Manual Draw-out type with ET2L trip unit EasyPact MVS ACB
    • SCHNEIDER, 4 Pole, 1250A, Manual Draw-out type with ET2L trip unit EasyPact MVS ACB

    SCHNEIDER, 4 Pole, 1250A, MANUAL DRAWOUT, EasyPact MVS ACB

    • Standalone (integration)
    • Facebook messenger (link)
    • WhatsApp (link)
    • Viber (link)
    • Skype (link)
    • Send an email (link)
    • Telegram (link)
    • Tawk.to (integration)
    • Facebook messenger (integration)
    • Crisp (integration)
    • Tidio (integration)

    Advantages of EasyPact MVS ACB

    • Thermal memory ensures safe tripping in case of consecutive faults
    • In-built ZSI feature facilitates intelligent discrimination and enhances installation life
    • Mechanical ready to close features checks all safety parameters before closing for enhanced safety
    • Trip unit with built in current & voltage metering for easy access to important electrical parameter
    • Best in class break time of 25ms creates lower stress on installation
    • Pollution degree 4 allows the breaker to operate in harsh environments
    • LED bargraph ensures easy access to % phase wise loading information
    • Ap protection feature standard in all trip unit
    • Single frame for 800A to 4000A
    • Suitability for applications up to 690V 
    • Flexible terminal orientation enables horizontal or vertical alignment chnages in the field

    EasyPact MVS Draw out ACB

    • Conforms to IS/ IEC 60947-2 & 3 
    • Microprocessor based ET trip systems with thermal memory 
    • No derating up to 50˚C  
    • Zone Selective Interlocking
    • Fully rated neutral with inbuilt protection
    • Pre trip alarm & individual fault indicating LEDs
    • ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
    • ET2L provides Overload & Short-circuit protections
    • Icu=Ics=Icw (1Sec)=50kA at 440V AC

    NoteAll draw-out type circuit breakers will be supplied with: (i) Top and Bottom horizontal terminations. (ii) 1 No. Electrical fault indication Contact (SDE). (iii) No. Auxiliary contact block (OF) with 4 C/O contacts. (iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP). All Electrical operated breakers are supplied with  motor mechnism (MCH), closing coil (XF) & shunt release (XF) 

     

    MVS12N4MW2L

    Data sheet

    ACB TRIP UNIT
    ET2L (without display)
    COUNTRY OF ORIGIN
    INDIA
    ACB BREAKING CAPACITY
    50kA
    ACB POLES
    4 POLE
    ACB PROTECTION TYPE
    MICROPROCESSOR BASED
    ACB RATING
    1250A
    ACB TYPE & VERSION
    MDO