PECO, 13-21A, 15HP, 3 Phase, PC-1.5 DOL STARTER
Features of DOL Starters
Type : PK – 1 (ISI Marked ) - Range : Up to 7.5 HP, 3 Phase.
Type : PC - Range : 10 HP to 50 HP, 3 Phase.
Fully conforms to IS/IEC : 60947(Part 4/Section1).
Type PK1 starters are ISI Marked . These starters consist of a Type PK1 Contactor and Thermal Overload Relay each bearing an
ISI Mark .
Type PC starters consist of a Type PC Contactor and Type PC/PNR Thermal Overload Relay each bearing an ISI Mark .
Most Reliable motor protection widely accepted in Agricultural as well as Industrial sector.
Guaranteed performance is assured due to world-class design and quality manufacturing of the starters.
Contactors and Relays are manufactured to withstand high ambient temperature, humidity and under voltage conditions.
Exceptionally long contact life of Air Break Contactor used in Motor Starter due to silver alloy contact tips and bounce free contacts.
Suitable for copper as well as aluminum conductors as per Indian Standards.
The sheet steel enclosure is robust, specially designed, Fabricated and powder coated to withstand adverse climatic condition.
It also acts under voltage release and protects motor from the effects of low voltage operations.
OFF Push button can be latched in OFF position to prevent accidental starting.
Wide range of Thermal Overload Relays, which can operate within temperature range of –5 ᵒC to 50 ᵒC ambient.
Wide range of coil voltages available.
Remotely controlled operation possible.
2 Nos. Earthing screws provided for protection.
Elegant in appearance and design.
প্রসঙ্গ
SK1O119 A
ডাটা সিট
MOTOR PHASES
TYPE OF STARTER
VOLTAGE RANGE
CONTACTOR COIL VOLTAGE
MOTOR STARTER MODEL
COUNTRY OF ORIGIN
MOTOR HP
MOTOR KW
MOTOR VOLTAGE
RELAY RANGE
অবস্থা
নতুন
16 other products in the same category
Three Phase DOL Starter in SS Enclosure. CS Series Starters available with contactor type CS1, CS2 & CS3 having 16A, 25A, 32A AC3 duty.
Heavy Duty DOL Starter Type DX-P with robust 4 Pole Contactor & LR1D OLR in SS Enclosure
MS132-T Circuit breakers for transformer protection are electro-mechanical protection devices specially designed to protect control transformers on the primary side. The short-circuit current setting is fixed to 20 times the operating current to handle the high inrush current generated by transformers..
Three Phase Auto start DOL Starter in SS Enclosure,Incorporating Heavy Duty 4 Pole Contactor type TC1-DX with wide band operating coil, Overload relay type LR3D with manual re-set and yellow flag for trip indication.
MO132 Manual motor starters with short circuit protection only